Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Rated operation power at AC-3, 230 V, 3-phase0.09kW
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 400 V0.18kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Rated operation current at AC-3, 400 V0.63A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current Ie0.6A
Overload release current setting0.4 - 0.63A
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Power consumption2.6W
Number of auxiliary contacts as normally open contact1
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally closed contact0
Ambient temperature, upper operating limit55°C
Release classCLASS 10 A
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
Number of indicator lights0
With transformerNo
Coordination class according to IEC 60947-4-3Class 2
Number of command positions0
Rail mounting possibleNo
Suitable for emergency stopNo
Degree of protection (IP)IP20
With fuseNo
External reset possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Supporting protocol for other bus systemsNo
Supporting protocol for SafetyBUS pNo
Width45mm
Height200mm
Depth154mm
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-0,63-M7(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=0.41A, Pmax=0.12kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 400 V

0.18kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Rated operation current at AC-3, 400 V

0.63A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

0.6A

Overload release current setting

0.4 .. 0.63A

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Power consumption

2.6W

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Number of auxiliary contacts as normally closed contact

0

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of indicator lights

0

With transformer

Coordination class according to IEC 60947-4-3

Class 2

Number of command positions

0

Rail mounting possible

Suitable for emergency stop

Degree of protection (IP)

IP20

With fuse

External reset possible

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

45mm

Height

200mm

Depth

154mm

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for EtherNet/IP

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.