Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated control supply voltage Us at DC0 - 0V
Rated operation power at AC-3, 400 V4kW
Voltage type for actuatingAC
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current Ie8.5A
Rated operation current at AC-3, 400 V10A
Overload release current setting6.3 - 10A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50A
Rated conditional short-circuit current, type 2, 400 V50A
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact0
Power consumption2.1W
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Type of electrical connection of main circuitSpring clamp connection
Release classCLASS 10 A
With transformerNo
Coordination class according to IEC 60947-4-3Class 2
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of command positions0
Rail mounting possibleNo
Suitable for emergency stopNo
External reset possibleNo
Number of indicator lights0
With fuseNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsNo
Width45mm
Supporting protocol for SafetyBUS pNo
Height214mm
Depth115mm
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-10-M11(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=8.5A, Pmax=4.0kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 400 V

4kW

Voltage type for actuating

AC

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

8.5A

Rated operation current at AC-3, 400 V

10A

Overload release current setting

6.3 .. 10A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated conditional short-circuit current, type 2, 400 V

50A

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Power consumption

2.1W

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Type of electrical connection of main circuit

Spring clamp connection

Release class

CLASS 10 A

With transformer

Coordination class according to IEC 60947-4-3

Class 2

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Number of command positions

0

Rail mounting possible

Suitable for emergency stop

External reset possible

Number of indicator lights

0

With fuse

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Width

45mm

Supporting protocol for SafetyBUS p

Height

214mm

Depth

115mm

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.