Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-D-10-M7(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=6.6A, Pmax=3.0kW, Sasy

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Voltage type for actuating
DC
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Release class
CLASS 10 A
Power consumption
2.6W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
100A
Rail mounting possible
Rated conditional short-circuit current, type 2, 230 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With short-circuit release
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally open contact
1
Number of command positions
0
With fuse
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
External reset possible
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Suitable for emergency stop
Supporting protocol for TCP/IP
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Degree of protection (NEMA)
Other
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET CBA
Number of indicator lights
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for PROFIsafe
With transformer
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for other bus systems
Width
45mm
Height
200mm
Depth
154mm
Rated operation power at AC-3, 400 V
3kW
Rated operation current Ie
6.6A
Overload release current setting
6.3 .. 10A
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
7A