Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Voltage type for actuatingAC
Rated control supply voltage Us at AC 50HZ230 - 230V
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC0 - 0V
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 400 V4kW
Rated operation current Ie8.5A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V9A
Overload release current setting6.3 - 10A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V150A
Number of auxiliary contacts as normally open contact1
Power consumption1.4W
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally closed contact0
Release classCLASS 10 A
Type of electrical connection of main circuitSpring clamp connection
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rail mounting possibleNo
With transformerNo
Number of command positions0
Suitable for emergency stopNo
Coordination class according to IEC 60947-4-3Class 1
Number of indicator lights0
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width45mm
Height197mm
Depth95mm
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Ambient temperature, upper operating limit55°C
External reset possibleNo
Supporting protocol for LONNo
Degree of protection (IP)IP20
With fuseNo
Degree of protection (NEMA)Other
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-10-M9(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=8.5A, Pmax=4.0kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 400 V

4kW

Rated operation current Ie

8.5A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

9A

Overload release current setting

6.3 .. 10A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

150A

Number of auxiliary contacts as normally open contact

1

Power consumption

1.4W

Temperature compensated overload protection

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10 A

Type of electrical connection of main circuit

Spring clamp connection

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rail mounting possible

With transformer

Number of command positions

0

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 1

Number of indicator lights

0

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

197mm

Depth

95mm

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Ambient temperature, upper operating limit

55°C

External reset possible

Supporting protocol for LON

Degree of protection (IP)

IP20

With fuse

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.