Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Voltage type for actuatingAC
Rated control supply voltage Us at AC 50HZ230 - 230V
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Rated conditional short-circuit current, type 2, 400 V150A
Number of auxiliary contacts as normally open contact1
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitSpring clamp connection
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of command positions0
Suitable for emergency stopNo
Coordination class according to IEC 60947-4-3Class 1
Number of indicator lights0
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Ambient temperature, upper operating limit55°C
External reset possibleNo
Supporting protocol for LONNo
Degree of protection (NEMA)Other
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Rated operation power at AC-3, 400 V4kW
Rated operation current Ie8.5A
Overload release current setting6.3 - 10A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC0 - 0V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V9A