Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC0 - 0V
Rated operation power at AC-3, 400 V5.5kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current Ie11.3A
Rated operation current at AC-3, 400 V12A
Overload release current setting8 - 12A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V50A
Ambient temperature, upper operating limit55°C
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 400 V50A
Power consumption2.1W
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width45mm
Height214mm
Depth115mm
With fuseNo
Number of indicator lights0
External reset possibleNo
Supporting protocol for TCP/IPNo
Degree of protection (NEMA)Other
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Release classCLASS 10 A
Number of command positions0
Type of electrical connection of main circuitSpring clamp connection
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rail mounting possibleNo
With transformerNo
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-12-M14(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=11.3A, Pmax=5.5kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated operation current at AC-3, 400 V

12A

Overload release current setting

8 .. 12A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

50A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 400 V

50A

Power consumption

2.1W

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

214mm

Depth

115mm

With fuse

Number of indicator lights

0

External reset possible

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for LON

Supporting protocol for PROFIBUS

Suitable for emergency stop

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for EtherNet/IP

Supporting protocol for Modbus

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Release class

CLASS 10 A

Number of command positions

0

Type of electrical connection of main circuit

Spring clamp connection

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rail mounting possible

With transformer

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (IP)

IP20