Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase4kW
Voltage type for actuatingDC
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
With transformerNo
Rated conditional short-circuit current, type 2, 230 V0A
Power consumption2.6W
Overload release current setting10 - 16A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection for auxiliary- and control current circuitScrew connection
Coordination class according to IEC 60947-4-3Class 1
Temperature compensated overload protectionYes
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Rail mounting possibleNo
Supporting protocol for CANNo
Number of command positions0
Type of electrical connection of main circuitScrew connection
Number of indicator lights0
Ambient temperature, upper operating limit55°C
With fuseNo
External reset possibleNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Degree of protection (NEMA)Other
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Rated operation current Ie15.2A
Rated operation power at AC-3, 400 V7.5kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated control supply voltage Us at DC24 - 24V
Release classCLASS 10 A
Supporting protocol for other bus systemsNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 400 V50A
Rated operation current at AC-3, 400 V15A
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Width45mm
Height200mm
Depth154mm
Supporting protocol for PROFINET CBANo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Degree of protection (IP)IP20
Supporting protocol for EtherNet/IPNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M15(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=11.3A, Pmax=5.5kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Voltage type for actuating

DC

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

With transformer

Rated conditional short-circuit current, type 2, 230 V

0A

Power consumption

2.6W

Overload release current setting

10 .. 16A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 1

Temperature compensated overload protection

Number of auxiliary contacts as normally open contact

1

Suitable for emergency stop

Rail mounting possible

Supporting protocol for CAN

Number of command positions

0

Type of electrical connection of main circuit

Screw connection

Number of indicator lights

0

Ambient temperature, upper operating limit

55°C

With fuse

External reset possible

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Rated operation current Ie

15.2A

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

24 .. 24V

Release class

CLASS 10 A

Supporting protocol for other bus systems

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 400 V

50A

Rated operation current at AC-3, 400 V

15A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Width

45mm

Height

200mm

Depth

154mm

Supporting protocol for PROFINET CBA

Supporting protocol for Modbus

Supporting protocol for ASI

Degree of protection (IP)

IP20

Supporting protocol for EtherNet/IP

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.