Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase4kW
Rated control supply voltage Us at DC24 - 24V
Overload release current setting10 - 16A
Rated operation power at AC-3, 400 V7.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
With short-circuit releaseYes
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated operation current Ie15.2A
Rated conditional short-circuit current, type 2, 230 V0A
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Supporting protocol for Data-HighwayNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Power consumption2.6W
Voltage type for actuatingDC
Supporting protocol for ASINo
Number of command positions0
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for CANNo
Release classCLASS 10 A
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Supporting protocol for ModbusNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Number of auxiliary contacts as normally open contact1
Rated operation current at AC-3, 400 V15A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width45mm
Height197mm
Depth95mm
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Number of indicator lights0
Number of auxiliary contacts as normally closed contact0
External reset possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for TCP/IPNo
Coordination class according to IEC 60947-4-3Class 1
Supporting protocol for EtherNet/IPNo
With transformerNo
Supporting protocol for LONNo
Suitable for emergency stopNo
Degree of protection (IP)IP20
Supporting protocol for PROFIBUSNo
Degree of protection (NEMA)Other
With fuseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M15(24VDC)-PI | Motor-starter combination direct, 24V DC control, Ie=16.0A, Pmax=7.5kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated control supply voltage Us at DC

24 .. 24V

Overload release current setting

10 .. 16A

Rated operation power at AC-3, 400 V

7.5kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

With short-circuit release

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated operation current Ie

15.2A

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Supporting protocol for Data-Highway

Rated power, 460 V, 60 Hz, 3-phase

0kW

Power consumption

2.6W

Voltage type for actuating

DC

Supporting protocol for ASI

Number of command positions

0

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for CAN

Release class

CLASS 10 A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Supporting protocol for Modbus

Rated power, 575 V, 60 Hz, 3-phase

0kW

Number of auxiliary contacts as normally open contact

1

Rated operation current at AC-3, 400 V

15A

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

197mm

Depth

95mm

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Number of indicator lights

0

Number of auxiliary contacts as normally closed contact

0

External reset possible

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for TCP/IP

Coordination class according to IEC 60947-4-3

Class 1

Supporting protocol for EtherNet/IP

With transformer

Supporting protocol for LON

Suitable for emergency stop

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Degree of protection (NEMA)

Other

With fuse

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.