Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 50HZ230 - 230V
With short-circuit releaseYes
Rated control supply voltage Us at DC0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase4kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 400 V7.5kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current Ie15.2A
Rated operation current at AC-3, 400 V16A
Overload release current setting10 - 16A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Power consumption2.1W
Number of auxiliary contacts as normally open contact1
Rated conditional short-circuit current, type 2, 400 V50A
Rated conditional short-circuit current, type 2, 230 V50A
Number of auxiliary contacts as normally closed contact0
Ambient temperature, upper operating limit55°C
Temperature compensated overload protectionYes
Release classCLASS 10 A
Number of command positions0
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Type of electrical connection of main circuitSpring clamp connection
With transformerNo
Rail mounting possibleNo
Coordination class according to IEC 60947-4-3Class 2
Suitable for emergency stopNo
Number of indicator lights0
External reset possibleNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
With fuseNo
Supporting protocol for other bus systemsNo
Height214mm
Depth115mm
Width45mm
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Degree of protection (NEMA)Other
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for LONNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M17(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=16.0A, Pmax=7.5kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

15.2A

Rated operation current at AC-3, 400 V

16A

Overload release current setting

10 .. 16A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Power consumption

2.1W

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 400 V

50A

Rated conditional short-circuit current, type 2, 230 V

50A

Number of auxiliary contacts as normally closed contact

0

Ambient temperature, upper operating limit

55°C

Temperature compensated overload protection

Release class

CLASS 10 A

Number of command positions

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Type of electrical connection of main circuit

Spring clamp connection

With transformer

Rail mounting possible

Coordination class according to IEC 60947-4-3

Class 2

Suitable for emergency stop

Number of indicator lights

0

External reset possible

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

With fuse

Supporting protocol for other bus systems

Height

214mm

Depth

115mm

Width

45mm

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for CAN

Degree of protection (NEMA)

Other

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for LON

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.