Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at DC24 - 24V
Rated operation power at AC-3, 230 V, 3-phase4kW
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Width45mm
Supporting protocol for other bus systemsNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of auxiliary contacts as normally closed contact0
With transformerNo
Release classCLASS 10 A
Temperature compensated overload protectionYes
Number of command positions0
Number of indicator lights0
Degree of protection (IP)IP20
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Suitable for emergency stopNo
Type of electrical connection of main circuitSpring clamp connection
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Rail mounting possibleNo
With fuseNo
Supporting protocol for CANNo
Rated conditional short-circuit current, type 2, 400 V50A
Supporting protocol for ModbusNo
External reset possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Rated operation power at AC-3, 400 V7.5kW
Height214mm
Overload release current setting10 - 16A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50A
Rated operation current Ie15.2A
Number of auxiliary contacts as normally open contact1
Depth115mm
Ambient temperature, upper operating limit55°C
Power consumption0.9W
Rated operation current at AC-3, 400 V16A
Voltage type for actuatingDC
Supporting protocol for Foundation FieldbusNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-16-M17(24VDC)-PI | Motor-starter combination direct, 24V DC control, Ie=16.0A, Pmax=7.5kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Rated operation power at AC-3, 230 V, 3-phase

4kW

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Width

45mm

Supporting protocol for other bus systems

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Number of auxiliary contacts as normally closed contact

0

With transformer

Release class

CLASS 10 A

Temperature compensated overload protection

Number of command positions

0

Number of indicator lights

0

Degree of protection (IP)

IP20

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Suitable for emergency stop

Type of electrical connection of main circuit

Spring clamp connection

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Rail mounting possible

With fuse

Supporting protocol for CAN

Rated conditional short-circuit current, type 2, 400 V

50A

Supporting protocol for Modbus

External reset possible

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for Data-Highway

Rated operation power at AC-3, 400 V

7.5kW

Height

214mm

Overload release current setting

10 .. 16A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated operation current Ie

15.2A

Number of auxiliary contacts as normally open contact

1

Depth

115mm

Ambient temperature, upper operating limit

55°C

Power consumption

0.9W

Rated operation current at AC-3, 400 V

16A

Voltage type for actuating

DC

Supporting protocol for Foundation Fieldbus

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for PROFIBUS

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.