Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase0.12kW
Rated control supply voltage Us at AC 50HZ230 - 230V
Voltage type for actuatingAC
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC0 - 0V
Rated operation power at AC-3, 400 V0.25kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
With short-circuit releaseYes
Rated operation current Ie0.8A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Rated operation current at AC-3, 400 V1A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Overload release current setting0.63 - 2A
Rated conditional short-circuit current, type 2, 400 V50A
Rated conditional short-circuit current, type 2, 230 V50A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Power consumption1.4W
Number of auxiliary contacts as normally closed contact0
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Number of auxiliary contacts as normally open contact1
Type of electrical connection of main circuitSpring clamp connection
Release classCLASS 10 A
Rail mounting possibleNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With transformerNo
Suitable for emergency stopNo
Number of indicator lights0
Number of command positions0
Coordination class according to IEC 60947-4-3Class 2
External reset possibleNo
With fuseNo
Degree of protection (NEMA)Other
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP20
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width45mm
Height197mm
Depth95mm
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-1-M7(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=0.8A, Pmax=0.25kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 400 V

0.25kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

With short-circuit release

Rated operation current Ie

0.8A

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Rated operation current at AC-3, 400 V

1A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

0.63 .. 2A

Rated conditional short-circuit current, type 2, 400 V

50A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Power consumption

1.4W

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally open contact

1

Type of electrical connection of main circuit

Spring clamp connection

Release class

CLASS 10 A

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With transformer

Suitable for emergency stop

Number of indicator lights

0

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

With fuse

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

197mm

Depth

95mm

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet