Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-D-1-M7(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=0.8A, Pmax=0.25kW, Sasy

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With short-circuit release
Rated control supply voltage Us at DC
24 .. 24V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 400 V
0.25kW
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.8A
Rated operation current at AC-3, 400 V
1A
Overload release current setting
0.63 .. 1A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
2.6W
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
1
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Coordination class according to IEC 60947-4-3
Class 2
Degree of protection (IP)
IP20
Supporting protocol for AS-Interface Safety at Work
Number of command positions
0
With fuse
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Height
200mm
Width
45mm
Depth
154mm
Supporting protocol for SUCONET
With transformer
Supporting protocol for PROFINET CBA
Number of indicator lights
0
Suitable for emergency stop
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for CAN
External reset possible
Supporting protocol for Foundation Fieldbus
Degree of protection (NEMA)
Other
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for LON