Type of motor starterDirect online starter (DOL)
Rated control supply voltage Us at DC0 - 0V
Rated control supply voltage Us at AC 50HZ230 - 230V
With short-circuit releaseYes
Rated operation power at AC-3, 400 V11kW
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Overload release current setting20 - 27A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 230 V50A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation current Ie21.7A
Rated conditional short-circuit current, type 2, 400 V50A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact1
Power consumption2.1W
Temperature compensated overload protectionYes
Release classCLASS 10 A
Degree of protection (IP)IP20
With fuseNo
Supporting protocol for INTERBUSNo
Suitable for emergency stopNo
Number of command positions0
Ambient temperature, upper operating limit55°C
Supporting protocol for ModbusNo
Coordination class according to IEC 60947-4-3Class 2
Degree of protection (NEMA)Other
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Rail mounting possibleNo
Supporting protocol for PROFIBUSNo
With transformerNo
Voltage type for actuatingAC
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of indicator lights0
Supporting protocol for other bus systemsNo
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Rated operation current at AC-3, 400 V25A
Width45mm
Height214mm
Depth115mm
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Data-HighwayNo
External reset possibleNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for TCP/IPNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-25-M25(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=21.7A, Pmax=11kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Rated operation power at AC-3, 400 V

11kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

0kW

Overload release current setting

20 .. 27A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

21.7A

Rated conditional short-circuit current, type 2, 400 V

50A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

1

Power consumption

2.1W

Temperature compensated overload protection

Release class

CLASS 10 A

Degree of protection (IP)

IP20

With fuse

Supporting protocol for INTERBUS

Suitable for emergency stop

Number of command positions

0

Ambient temperature, upper operating limit

55°C

Supporting protocol for Modbus

Coordination class according to IEC 60947-4-3

Class 2

Degree of protection (NEMA)

Other

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for SUCONET

Rail mounting possible

Supporting protocol for PROFIBUS

With transformer

Voltage type for actuating

AC

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Number of indicator lights

0

Supporting protocol for other bus systems

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Rated operation current at AC-3, 400 V

25A

Width

45mm

Height

214mm

Depth

115mm

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for Data-Highway

External reset possible

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for PROFINET IO