Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Rated operation power at AC-3, 230 V, 3-phase5.5kW
Rated operation current Ie21.7A
Rated operation current at AC-3, 400 V25A
Rated operation power at AC-3, 400 V11kW
Overload release current setting20 - 25A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Number of auxiliary contacts as normally closed contact0
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rail mounting possibleNo
Power consumption0.9W
Rated conditional short-circuit current, type 2, 400 V50000A
Number of auxiliary contacts as normally open contact1
Ambient temperature, upper operating limit55°C
Number of indicator lights0
With transformerNo
Rated conditional short-circuit current, type 2, 230 V50000A
Release classCLASS 10 A
Supporting protocol for INTERBUSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Degree of protection (NEMA)Other
Supporting protocol for TCP/IPNo
With fuseNo
Coordination class according to IEC 60947-4-3Class 2
Suitable for emergency stopNo
Supporting protocol for SUCONETNo
External reset possibleNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Temperature compensated overload protectionYes
Type of electrical connection of main circuitScrew connection
Number of command positions0
Degree of protection (IP)IP00
Supporting protocol for PROFINET CBANo
Rated control supply voltage Us at DC24 - 24V
Width45mm
Height200mm
Depth156mm
Voltage type for actuatingDC
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for LONNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for CANNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-25-M25(24VDC)/BBA | Motor-starter combination direct, 24V DC control, Ie=21.7A, Pmax=11kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Rated operation power at AC-3, 230 V, 3-phase

5.5kW

Rated operation current Ie

21.7A

Rated operation current at AC-3, 400 V

25A

Rated operation power at AC-3, 400 V

11kW

Overload release current setting

20 .. 25A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rail mounting possible

Power consumption

0.9W

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally open contact

1

Ambient temperature, upper operating limit

55°C

Number of indicator lights

0

With transformer

Rated conditional short-circuit current, type 2, 230 V

50000A

Release class

CLASS 10 A

Supporting protocol for INTERBUS

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

With fuse

Coordination class according to IEC 60947-4-3

Class 2

Suitable for emergency stop

Supporting protocol for SUCONET

External reset possible

Supporting protocol for PROFIBUS

Supporting protocol for PROFINET IO

Temperature compensated overload protection

Type of electrical connection of main circuit

Screw connection

Number of command positions

0

Degree of protection (IP)

IP00

Supporting protocol for PROFINET CBA

Rated control supply voltage Us at DC

24 .. 24V

Width

45mm

Height

200mm

Depth

156mm

Voltage type for actuating

DC

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for CAN

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.