Technical specifications
MSC-D-25-M25(24VDC)-PI | Motor-starter combination direct, 24V DC control, Ie=21.7A, Pmax=11kW,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
5.5kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 400 V
11kW
Rated control supply voltage Us at DC
24 .. 24V
Rated operation current Ie
21.7A
Rated operation current at AC-3, 400 V
25A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Overload release current setting
20 .. 26A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
50A
Power consumption
0.9W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
214mm
Depth
115mm
External reset possible
Supporting protocol for TCP/IP
Degree of protection (IP)
IP20
Supporting protocol for ASI
Rated conditional short-circuit current, type 2, 400 V
50A
Ambient temperature, upper operating limit
55°C
Supporting protocol for DeviceNet
Temperature compensated overload protection
Supporting protocol for Modbus
Number of command positions
0
Rail mounting possible
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Degree of protection (NEMA)
Other
With fuse
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for INTERBUS
Number of auxiliary contacts as normally closed contact
0
Release class
CLASS 10 A
Number of auxiliary contacts as normally open contact
1
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Type of electrical connection of main circuit
Spring clamp connection
With transformer
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus