Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation power at AC-3, 400 V2.2kW
Rated conditional short-circuit current, type 2, 400 V50A
Overload release current setting4 - 6.3A
Number of auxiliary contacts as normally open contact1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Power consumption1.4W
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Rated operation current at AC-3, 400 V6.3A
Number of command positions0
Release classCLASS 10 A
External reset possibleNo
Temperature compensated overload protectionYes
Type of electrical connection of main circuitSpring clamp connection
With transformerNo
Ambient temperature, upper operating limit55°C
Number of auxiliary contacts as normally closed contact0
Rail mounting possibleNo
Degree of protection (IP)IP20
With fuseNo
Number of indicator lights0
Degree of protection (NEMA)Other
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SUCONETNo
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation current Ie5A
Rated conditional short-circuit current, type 2, 230 V50A
Voltage type for actuatingAC
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for other bus systemsNo
Width45mm
Depth95mm
Height197mm
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-6,3-M7(230V50HZ)-PI | Motor-starter combination direct, 230V AC control, Ie=5.0A, Pmax=2.2kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation power at AC-3, 400 V

2.2kW

Rated conditional short-circuit current, type 2, 400 V

50A

Overload release current setting

4 .. 6.3A

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Power consumption

1.4W

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated operation current at AC-3, 400 V

6.3A

Number of command positions

0

Release class

CLASS 10 A

External reset possible

Temperature compensated overload protection

Type of electrical connection of main circuit

Spring clamp connection

With transformer

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Rail mounting possible

Degree of protection (IP)

IP20

With fuse

Number of indicator lights

0

Degree of protection (NEMA)

Other

Suitable for emergency stop

Supporting protocol for TCP/IP

Supporting protocol for EtherNet/IP

Supporting protocol for SUCONET

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current Ie

5A

Rated conditional short-circuit current, type 2, 230 V

50A

Voltage type for actuating

AC

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for other bus systems

Width

45mm

Depth

95mm

Height

197mm

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for LON

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.