Technical specifications

Type of motor starterDirect online starter (DOL)
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Supporting protocol for DeviceNet SafetyNo
Rated control supply voltage Us at AC 50HZ0 - 0V
Rated control supply voltage Us at AC 60HZ0 - 0V
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Overload release current setting4 - 6.3A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Power consumption2.6W
Rated operation power at AC-3, 400 V2.2kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 2, 230 V50A
Rated operation current at AC-3, 400 V6.3A
Suitable for emergency stopNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Type of electrical connection of main circuitSpring clamp connection
Degree of protection (IP)IP20
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With transformerNo
Number of auxiliary contacts as normally open contact1
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated operation current Ie5A
Supporting protocol for ModbusNo
Temperature compensated overload protectionYes
Supporting protocol for Data-HighwayNo
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50A
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Degree of protection (NEMA)Other
Supporting protocol for ASINo
Number of indicator lights0
Supporting protocol for DeviceNetNo
Number of command positions0
With fuseNo
Supporting protocol for LONNo
Supporting protocol for Foundation FieldbusNo
Rail mounting possibleNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSNo
Release classCLASS 10 A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for other bus systemsNo
External reset possibleNo
Supporting protocol for PROFINET CBANo
Width45mm
Height197mm
Depth95mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-6,3-M7(24VDC)-PI | Motor-starter combination direct, 24V DC control, Ie=5.0A, Pmax=2.2kW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Supporting protocol for DeviceNet Safety

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

DC

Rated control supply voltage Us at DC

24 .. 24V

Overload release current setting

4 .. 6.3A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Power consumption

2.6W

Rated operation power at AC-3, 400 V

2.2kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 2, 230 V

50A

Rated operation current at AC-3, 400 V

6.3A

Suitable for emergency stop

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of electrical connection of main circuit

Spring clamp connection

Degree of protection (IP)

IP20

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With transformer

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current Ie

5A

Supporting protocol for Modbus

Temperature compensated overload protection

Supporting protocol for Data-Highway

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50A

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

Degree of protection (NEMA)

Other

Supporting protocol for ASI

Number of indicator lights

0

Supporting protocol for DeviceNet

Number of command positions

0

With fuse

Supporting protocol for LON

Supporting protocol for Foundation Fieldbus

Rail mounting possible

Supporting protocol for INTERBUS

Supporting protocol for CAN

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for PROFIBUS

Release class

CLASS 10 A

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for other bus systems

External reset possible

Supporting protocol for PROFINET CBA

Width

45mm

Height

197mm

Depth

95mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.