

Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-0,25-M7(24VDC)-PI | Motor-starter combination reversing, 24V DC control, Ie=0.21A, PMAX0.06KW,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
0.06kW
Rated operation power at AC-3, 230 V, 3-phase
0.04kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
0.21A
Rated operation current at AC-3, 400 V
0.25A
Overload release current setting
0.25 .. 0.25A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 230 V
50A
Power consumption
2.6W
Rated conditional short-circuit current, type 2, 400 V
50A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Type of electrical connection of main circuit
Spring clamp connection
Rail mounting possible
With transformer
Number of command positions
0
Degree of protection (IP)
IP20
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
Suitable for emergency stop
External reset possible
With fuse
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
90mm
Height
197mm
Depth
95mm
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS