Technical specifications
MSC-R-0,4-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=0.31A,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 230 V, 3-phase
0.06kW
Rated operation power at AC-3, 400 V
0.09kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at DC
0 .. 0V
Rated operation current at AC-3, 400 V
0.4A
Overload release current setting
0.4 .. 0.4A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Width
90mm
Height
197mm
Depth
95mm
Supporting protocol for other bus systems
With transformer
Suitable for emergency stop
Release class
CLASS 10 A
Power consumption
1.4W
Number of auxiliary contacts as normally closed contact
0
Number of command positions
0
Number of indicator lights
0
Ambient temperature, upper operating limit
55°C
With fuse
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Degree of protection (IP)
IP20
External reset possible
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for LON
Degree of protection (NEMA)
Other
Rated conditional short-circuit current, type 2, 230 V
50A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
0.31A
Rated conditional short-circuit current, type 2, 400 V
50A
Temperature compensated overload protection
Coordination class according to IEC 60947-4-3
Class 2
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS