Technical specifications

Type of motor starterReversing starter
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ230 - 230V
Voltage type for actuatingAC
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation power at AC-3, 230 V, 3-phase0.06kW
Rated operation power at AC-3, 400 V0.09kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated control supply voltage Us at DC0 - 0V
Rated operation current at AC-3, 400 V0.4A
Overload release current setting0.4 - 0.4A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Width90mm
Height197mm
Depth95mm
Supporting protocol for other bus systemsNo
With transformerNo
Suitable for emergency stopNo
Release classCLASS 10 A
Power consumption1.4W
Number of auxiliary contacts as normally closed contact0
Number of command positions0
Number of indicator lights0
Ambient temperature, upper operating limit55°C
With fuseNo
Rail mounting possibleNo
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFINET IONo
Degree of protection (IP)IP20
External reset possibleNo
Supporting protocol for DeviceNetNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Supporting protocol for LONNo
Degree of protection (NEMA)Other
Rated conditional short-circuit current, type 2, 230 V50A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated operation current Ie0.31A
Rated conditional short-circuit current, type 2, 400 V50A
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 2
Type of electrical connection of main circuitSpring clamp connection
Number of auxiliary contacts as normally open contact0
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-0,4-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=0.31A,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

0.06kW

Rated operation power at AC-3, 400 V

0.09kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

0 .. 0V

Rated operation current at AC-3, 400 V

0.4A

Overload release current setting

0.4 .. 0.4A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Width

90mm

Height

197mm

Depth

95mm

Supporting protocol for other bus systems

With transformer

Suitable for emergency stop

Release class

CLASS 10 A

Power consumption

1.4W

Number of auxiliary contacts as normally closed contact

0

Number of command positions

0

Number of indicator lights

0

Ambient temperature, upper operating limit

55°C

With fuse

Rail mounting possible

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for PROFINET IO

Degree of protection (IP)

IP20

External reset possible

Supporting protocol for DeviceNet

Supporting protocol for Foundation Fieldbus

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Supporting protocol for LON

Degree of protection (NEMA)

Other

Rated conditional short-circuit current, type 2, 230 V

50A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current Ie

0.31A

Rated conditional short-circuit current, type 2, 400 V

50A

Temperature compensated overload protection

Coordination class according to IEC 60947-4-3

Class 2

Type of electrical connection of main circuit

Spring clamp connection

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS