Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterReversing starter
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated control supply voltage Us at AC 60HZ0 - 0V
With short-circuit releaseYes
Rated control supply voltage Us at DC0 - 0V
Voltage type for actuatingAC
Rated operation power at AC-3, 400 V5.5kW
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current Ie11.3A
Rated power, 575 V, 60 Hz, 3-phase0kW
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width90mm
Depth95mm
Height197mm
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 2, 400 V50000A
Release classCLASS 10 A
Number of command positions0
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitSpring clamp connection
Rail mounting possibleNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of indicator lights0
Coordination class according to IEC 60947-4-3Class 1
Rated operation current at AC-3, 400 V12A
Supporting protocol for INTERBUSNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Overload release current setting8 - 12A
Power consumption1.4W
With transformerNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Number of auxiliary contacts as normally open contact0
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Degree of protection (NEMA)Other
Temperature compensated overload protectionYes
Degree of protection (IP)IP20
External reset possibleNo
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-12-M12(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=11.3A,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

5.5kW

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

90mm

Depth

95mm

Height

197mm

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 2, 400 V

50000A

Release class

CLASS 10 A

Number of command positions

0

Suitable for emergency stop

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Spring clamp connection

Rail mounting possible

With fuse

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Number of indicator lights

0

Coordination class according to IEC 60947-4-3

Class 1

Rated operation current at AC-3, 400 V

12A

Supporting protocol for INTERBUS

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Overload release current setting

8 .. 12A

Power consumption

1.4W

With transformer

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Number of auxiliary contacts as normally open contact

0

Supporting protocol for DeviceNet

Supporting protocol for LON

Degree of protection (NEMA)

Other

Temperature compensated overload protection

Degree of protection (IP)

IP20

External reset possible

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.