Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starterReversing starter
Supporting protocol for AS-Interface Safety at WorkNo
With short-circuit releaseYes
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at DC0 - 0V
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase4kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 400 V7.5kW
Rated operation current Ie15.2A
Rated operation current at AC-3, 400 V15A
Overload release current setting10 - 16A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 2, 400 V50000A
Rated conditional short-circuit current, type 2, 230 V0A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Power consumption1.4W
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Width90mm
Height197mm
Depth95mm
External reset possibleNo
Number of auxiliary contacts as normally closed contact0
Release classCLASS 10 A
Degree of protection (NEMA)Other
Suitable for emergency stopNo
Supporting protocol for Data-HighwayNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNetNo
Number of indicator lights0
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Rail mounting possibleNo
Supporting protocol for TCP/IPNo
Coordination class according to IEC 60947-4-3Class 1
Degree of protection (IP)IP20
Supporting protocol for Foundation FieldbusNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Temperature compensated overload protectionYes
With transformerNo
Ambient temperature, upper operating limit55°C
Number of auxiliary contacts as normally open contact0
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
With fuseNo
Number of command positions0
Supporting protocol for SERCOSNo
Supporting protocol for LONNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-16-M15(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=16.0A,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

Supporting protocol for AS-Interface Safety at Work

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at DC

0 .. 0V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

4kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 400 V

7.5kW

Rated operation current Ie

15.2A

Rated operation current at AC-3, 400 V

15A

Overload release current setting

10 .. 16A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 400 V

50000A

Rated conditional short-circuit current, type 2, 230 V

0A

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Power consumption

1.4W

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

90mm

Height

197mm

Depth

95mm

External reset possible

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10 A

Degree of protection (NEMA)

Other

Suitable for emergency stop

Supporting protocol for Data-Highway

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet

Number of indicator lights

0

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Rail mounting possible

Supporting protocol for TCP/IP

Coordination class according to IEC 60947-4-3

Class 1

Degree of protection (IP)

IP20

Supporting protocol for Foundation Fieldbus

Supporting protocol for CAN

Supporting protocol for INTERBUS

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Temperature compensated overload protection

With transformer

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

With fuse

Number of command positions

0

Supporting protocol for SERCOS

Supporting protocol for LON

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.