Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-1-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=0.8A, PMAX0.25KW,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of motor starter
Reversing starter
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 .. 0V
Rated operation power at AC-3, 400 V
0.25kW
Rated operation current at AC-3, 400 V
1A
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
1.4W
Ambient temperature, upper operating limit
55°C
Rated operation power at AC-3, 230 V, 3-phase
0.12kW
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Overload release current setting
0.63 .. 4A
Rated conditional short-circuit current, type 2, 230 V
50A
Rated operation current Ie
0.8A
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 400 V
50A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
90mm
Degree of protection (IP)
IP20
Height
197mm
With transformer
Release class
CLASS 10 A
Supporting protocol for PROFIBUS
Suitable for emergency stop
External reset possible
Number of indicator lights
0
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for SUCONET
With fuse
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for CAN
Depth
95mm
Supporting protocol for INTERBUS
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Type of electrical connection of main circuit
Spring clamp connection
Temperature compensated overload protection
Number of command positions
0
Rail mounting possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP