Technical specifications

Type of motor starterReversing starter
With short-circuit releaseYes
Rated operation power at AC-3, 400 V0.25kW
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase0.12kW
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated operation current Ie0.8A
Overload release current setting0.63 - 3A
Power consumption2.6W
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleNo
Type of electrical connection of main circuitSpring clamp connection
Number of auxiliary contacts as normally open contact0
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated control supply voltage Us at DC24 - 24V
Rated conditional short-circuit current, type 2, 400 V50A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
External reset possibleNo
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V1A
Rated conditional short-circuit current, type 2, 230 V50A
With transformerNo
Number of auxiliary contacts as normally closed contact0
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Coordination class according to IEC 60947-4-3Class 2
Ambient temperature, upper operating limit55°C
Number of command positions0
Temperature compensated overload protectionYes
Suitable for emergency stopNo
Release classCLASS 10 A
With fuseNo
Number of indicator lights0
Degree of protection (IP)IP20
Supporting protocol for CANNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIBUSNo
Degree of protection (NEMA)Other
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Width90mm
Supporting protocol for other bus systemsNo
Height197mm
Depth95mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-1-M7(24VDC)-PI | Motor-starter combination reversing, 24V DC control, Ie=0.8A, PMAX0.25KW,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

With short-circuit release

Rated operation power at AC-3, 400 V

0.25kW

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

0.12kW

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation current Ie

0.8A

Overload release current setting

0.63 .. 3A

Power consumption

2.6W

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Type of electrical connection of main circuit

Spring clamp connection

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated control supply voltage Us at DC

24 .. 24V

Rated conditional short-circuit current, type 2, 400 V

50A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

External reset possible

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

1A

Rated conditional short-circuit current, type 2, 230 V

50A

With transformer

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Coordination class according to IEC 60947-4-3

Class 2

Ambient temperature, upper operating limit

55°C

Number of command positions

0

Temperature compensated overload protection

Suitable for emergency stop

Release class

CLASS 10 A

With fuse

Number of indicator lights

0

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIBUS

Degree of protection (NEMA)

Other

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Width

90mm

Supporting protocol for other bus systems

Height

197mm

Depth

95mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.