Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-4-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=2.6A, PMAX1.1KW,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at AC 50HZ
230 .. 230V
With short-circuit release
Rated control supply voltage Us at DC
0 .. 0V
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated operation power at AC-3, 400 V
1.5kW
Rated operation current Ie
3.6A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Overload release current setting
2.5 .. 4A
Rated operation current at AC-3, 400 V
4A
Rated conditional short-circuit current, type 2, 230 V
50A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 2, 400 V
50A
Number of auxiliary contacts as normally open contact
0
Power consumption
1.4W
Rail mounting possible
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Ambient temperature, upper operating limit
55°C
Type of electrical connection of main circuit
Spring clamp connection
With transformer
Suitable for emergency stop
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
90mm
Height
197mm
Depth
95mm
Supporting protocol for SUCONET
Supporting protocol for ASI
Supporting protocol for PROFINET CBA
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for EtherNet/IP
Supporting protocol for Data-Highway
External reset possible
Number of command positions
0
Number of indicator lights
0
Supporting protocol for INTERBUS
Coordination class according to IEC 60947-4-3
Class 2
With fuse
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Supporting protocol for LON
Degree of protection (IP)
IP20
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for TCP/IP