Details
- •Low-voltage industrial components
- •Motor starter/motor starter combination
- •1 KOM
- •EATON
Technical specifications
MSC-R-6,3-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=5.0A,

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
Rated operation power at AC-3, 400 V
2.2kW
Voltage type for actuating
AC
With short-circuit release
Overload release current setting
4 .. 6.3A
Rated conditional short-circuit current, type 2, 230 V
50A
Rated operation current at AC-3, 400 V
6.3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
5A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Power consumption
1.4W
Rail mounting possible
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Number of command positions
0
Suitable for emergency stop
Release class
CLASS 10 A
With fuse
Ambient temperature, upper operating limit
55°C
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for INTERBUS
With transformer
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for PROFIBUS
Temperature compensated overload protection
Rated control supply voltage Us at DC
0 .. 0V
Supporting protocol for Modbus
Supporting protocol for ASI
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for Data-Highway
Rated conditional short-circuit current, type 2, 400 V
50A
Degree of protection (NEMA)
Other
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for DeviceNet
Number of auxiliary contacts as normally open contact
0
Supporting protocol for LON
Degree of protection (IP)
IP20
External reset possible
Number of indicator lights
0
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Width
90mm
Height
197mm
Depth
95mm