Technical specifications

Type of motor starterReversing starter
Rated operation power at AC-3, 400 V2.2kW
Voltage type for actuatingAC
With short-circuit releaseYes
Overload release current setting4 - 6.3A
Rated conditional short-circuit current, type 2, 230 V50A
Rated operation current at AC-3, 400 V6.3A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated operation current Ie5A
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Power consumption1.4W
Rail mounting possibleNo
Rated power, 575 V, 60 Hz, 3-phase0kW
Type of electrical connection for auxiliary- and control current circuitSpring clamp connection
Number of command positions0
Suitable for emergency stopNo
Release classCLASS 10 A
With fuseNo
Ambient temperature, upper operating limit55°C
Coordination class according to IEC 60947-4-3Class 2
Supporting protocol for INTERBUSNo
With transformerNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Supporting protocol for PROFIBUSNo
Temperature compensated overload protectionYes
Rated control supply voltage Us at DC0 - 0V
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for Data-HighwayNo
Rated conditional short-circuit current, type 2, 400 V50A
Degree of protection (NEMA)Other
Number of auxiliary contacts as normally closed contact0
Supporting protocol for DeviceNetNo
Number of auxiliary contacts as normally open contact0
Supporting protocol for LONNo
Degree of protection (IP)IP20
External reset possibleNo
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsNo
Width90mm
Height197mm
Depth95mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-R-6,3-M7(230V50HZ)-PI | Motor-starter combination reversing, 230V AC control, Ie=5.0A,

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

Rated operation power at AC-3, 400 V

2.2kW

Voltage type for actuating

AC

With short-circuit release

Overload release current setting

4 .. 6.3A

Rated conditional short-circuit current, type 2, 230 V

50A

Rated operation current at AC-3, 400 V

6.3A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current Ie

5A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Power consumption

1.4W

Rail mounting possible

Rated power, 575 V, 60 Hz, 3-phase

0kW

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Number of command positions

0

Suitable for emergency stop

Release class

CLASS 10 A

With fuse

Ambient temperature, upper operating limit

55°C

Coordination class according to IEC 60947-4-3

Class 2

Supporting protocol for INTERBUS

With transformer

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Supporting protocol for PROFIBUS

Temperature compensated overload protection

Rated control supply voltage Us at DC

0 .. 0V

Supporting protocol for Modbus

Supporting protocol for ASI

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for Data-Highway

Rated conditional short-circuit current, type 2, 400 V

50A

Degree of protection (NEMA)

Other

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for DeviceNet

Number of auxiliary contacts as normally open contact

0

Supporting protocol for LON

Degree of protection (IP)

IP20

External reset possible

Number of indicator lights

0

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Width

90mm

Height

197mm

Depth

95mm

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.