Technical specifications

Output, voltageNo
Input signal, configurableNo
Voltage type of supply voltageDC
Resolution of the analogue inputs16Bit
Input, resistorNo
Output, currentNo
Supply voltage DC19.2 - 30V
Input, currentYes
Input, resistance thermometerNo
Input, voltageNo
Input, thermocoupleNo
Number of HW-interfaces industrial Ethernet0
Analogue inputs configurableNo
Analogue outputs configurableNo
Number of analogue inputs8
Output signal configurableNo
Number of interfaces PROFINET0
Number of analogue outputs0
Number of HW-interfaces RS-2320
Number of HW-interfaces Wireless0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for EtherCATNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for PROFIsafeNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SafetyBUS pNo
Radio standard UMTSNo
Radio standard GSMNo
System accessoryYes
Degree of protection (IP)IP20
Radio standard BluetoothNo
Type of electric connectionOther
Rail mounting possibleYes
Fieldbus connection over separate bus coupler possibleYes
IO link masterNo
Radio standard GPRSNo
Wall mounting/direct mountingYes
Front built-in possibleNo
Appendant operation agent (Ex ia)No
Rack-assembly possibleNo
Suitable for safety functionsYes
Height125.894343mm
Explosion safety category for gasNone
Explosion safety category for dustNone
Width53.6mm
Appendant operation agent (Ex ib)No
Performance level according to EN ISO 13849-1None
Depth52.59mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1061424 | AXL F PSAI8 I 1F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Output, voltage

Input signal, configurable

Voltage type of supply voltage

DC

Resolution of the analogue inputs

16Bit

Input, resistor

Output, current

Supply voltage DC

19.2 .. 30V

Input, current

Input, resistance thermometer

Input, voltage

Input, thermocouple

Number of HW-interfaces industrial Ethernet

0

Analogue inputs configurable

Analogue outputs configurable

Number of analogue inputs

8

Output signal configurable

Number of interfaces PROFINET

0

Number of analogue outputs

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for EtherCAT

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for EtherNet/IP

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Radio standard Wi-Fi 802.11

Supporting protocol for SafetyBUS p

Radio standard UMTS

Radio standard GSM

System accessory

Degree of protection (IP)

IP20

Radio standard Bluetooth

Type of electric connection

Other

Rail mounting possible

Fieldbus connection over separate bus coupler possible

IO link master

Radio standard GPRS

Wall mounting/direct mounting

Front built-in possible

Appendant operation agent (Ex ia)

Rack-assembly possible

Suitable for safety functions

Height

125.894343mm

Explosion safety category for gas

None

Explosion safety category for dust

None

Width

53.6mm

Appendant operation agent (Ex ib)

Performance level according to EN ISO 13849-1

None

Depth

52.59mm