Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Input, resistance thermometerNo
Input, voltageNo
Input, currentYes
Input, resistorNo
Input signal, configurableYes
Input, thermocoupleNo
Output, voltageNo
Output, currentNo
Voltage type of supply voltageDC
Number of analogue inputs8
Output signal configurableNo
Analogue inputs configurableYes
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs0
Analogue outputs configurableNo
Number of interfaces PROFINET0
Resolution of the analogue inputs12Bit
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces Wireless0
Number of HW-interfaces RS-4850
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces other0
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for EtherCATNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNet SafetyNo
Radio standard BluetoothNo
Radio standard UMTSNo
System accessoryYes
IO link masterNo
Radio standard GPRSNo
Fieldbus connection over separate bus coupler possibleYes
Radio standard Wi-Fi 802.11No
Supporting protocol for SafetyBUS pNo
Rail mounting possibleYes
Type of electric connectionOther
Wall mounting/direct mountingYes
Degree of protection (IP)IP20
Radio standard GSMNo
Supporting protocol for PROFIsafeNo
Front built-in possibleNo
Suitable for safety functionsNo
Appendant operation agent (Ex ia)No
Performance level according to EN ISO 13849-1None
Explosion safety category for dustNone
Explosion safety category for gasNone
Depth77.1mm
Width53.6mm
Appendant operation agent (Ex ib)No
Height126.1mm
Rack-assembly possibleNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1215392 | AXL P AI8 P HART 1F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Input, resistance thermometer

Input, voltage

Input, current

Input, resistor

Input signal, configurable

Input, thermocouple

Output, voltage

Output, current

Voltage type of supply voltage

DC

Number of analogue inputs

8

Output signal configurable

Analogue inputs configurable

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

0

Analogue outputs configurable

Number of interfaces PROFINET

0

Resolution of the analogue inputs

12Bit

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for EtherCAT

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for DeviceNet Safety

Radio standard Bluetooth

Radio standard UMTS

System accessory

IO link master

Radio standard GPRS

Fieldbus connection over separate bus coupler possible

Radio standard Wi-Fi 802.11

Supporting protocol for SafetyBUS p

Rail mounting possible

Type of electric connection

Other

Wall mounting/direct mounting

Degree of protection (IP)

IP20

Radio standard GSM

Supporting protocol for PROFIsafe

Front built-in possible

Suitable for safety functions

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Explosion safety category for dust

None

Explosion safety category for gas

None

Depth

77.1mm

Width

53.6mm

Appendant operation agent (Ex ib)

Height

126.1mm

Rack-assembly possible