Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Digital inputs configurableNo
Input current at signal 10.0025mA
Digital outputs configurableNo
Number of interfaces PROFINET0
Type of voltage (input voltage)DC
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Short-circuit protection, outputs availableNo
Type of digital outputNone
Number of digital outputs16
Number of digital inputs16
Voltage type of supply voltageDC
Permitted voltage at input0 - 5V
Number of HW-interfaces RS-2320
Permitted voltage at output24 - 24V
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for EtherCATNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Radio standard BluetoothNo
Radio standard GSMNo
Radio standard GPRSNo
Radio standard Wi-Fi 802.11No
Time delay at signal exchange0 - 0ms
Supporting protocol for other bus systemsYes
Radio standard UMTSNo
Degree of protection (IP)Other
Front built-in possibleNo
Wall mounting/direct mountingNo
System accessoryYes
Rail mounting possibleNo
Rack-assembly possibleNo
IO link masterNo
Suitable for safety functionsNo
Fieldbus connection over separate bus coupler possibleYes
SIL according to IEC 61508None
Appendant operation agent (Ex ia)No
Performance level according to EN ISO 13849-1None
Explosion safety category for gasNone
Appendant operation agent (Ex ib)No
Width59.8mm
Height212mm
Depth30.2mm
Explosion safety category for dustNone

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1300915 | AXL E PN DIO16 M12 6M-L

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Digital inputs configurable

Input current at signal 1

0.0025mA

Digital outputs configurable

Number of interfaces PROFINET

0

Type of voltage (input voltage)

DC

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Short-circuit protection, outputs available

Type of digital output

None

Number of digital outputs

16

Number of digital inputs

16

Voltage type of supply voltage

DC

Permitted voltage at input

0 .. 5V

Number of HW-interfaces RS-232

0

Permitted voltage at output

24 .. 24V

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

0

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for EtherCAT

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Number of HW-interfaces other

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Data-Highway

Number of HW-interfaces Wireless

0

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Radio standard Bluetooth

Radio standard GSM

Radio standard GPRS

Radio standard Wi-Fi 802.11

Time delay at signal exchange

0 .. 0ms

Supporting protocol for other bus systems

Radio standard UMTS

Degree of protection (IP)

Other

Front built-in possible

Wall mounting/direct mounting

System accessory

Rail mounting possible

Rack-assembly possible

IO link master

Suitable for safety functions

Fieldbus connection over separate bus coupler possible

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Explosion safety category for gas

None

Appendant operation agent (Ex ib)

Width

59.8mm

Height

212mm

Depth

30.2mm

Explosion safety category for dust

None