Technical specifications

System configuration TNNo
System configuration DCNo
System configuration TN-CNo
System configuration ITNo
System configuration TTNo
System configuration TN-C-SNo
System configuration otherNo
Voltage protection level L-N2.1kV
Nominal discharge surge current (8/20)20kA
Max. overcurrent protection device, series connection (fuse)80A
Max. continuous voltage AC440V
Max. discharge surge current (8/20)40kA
Integrated backup fuseYes
Short-circuit breaking capacity (Isccr)50kA
Voltage protection level2.5kV
System configuration TN-SYes
Max. overcurrent protection device, parallel connection (fuse)315A
Voltage protection level N-PE2.5kV
Leakage-current freeNo
Signalling at the deviceOptic
Max. conductor cross section solid (solid, stranded)1.5mm²
Construction sizeOther
Max. conductor cross section flexible (fine-strand)35mm²
Mounting methodDIN rail (top hat rail) 35 mm
With remote signalling contactYes
Category type 2Yes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1466617 | VAL-SPP-T2-440-3+1-UT-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • PHOENIX

Technical specifications

System configuration TN

System configuration DC

System configuration TN-C

System configuration IT

System configuration TT

System configuration TN-C-S

System configuration other

Voltage protection level L-N

2.1kV

Nominal discharge surge current (8/20)

20kA

Max. overcurrent protection device, series connection (fuse)

80A

Max. continuous voltage AC

440V

Max. discharge surge current (8/20)

40kA

Integrated backup fuse

Short-circuit breaking capacity (Isccr)

50kA

Voltage protection level

2.5kV

System configuration TN-S

Max. overcurrent protection device, parallel connection (fuse)

315A

Voltage protection level N-PE

2.5kV

Leakage-current free

Signalling at the device

Optic

Max. conductor cross section solid (solid, stranded)

1.5mm²

Construction size

Other

Max. conductor cross section flexible (fine-strand)

35mm²

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Category type 2