Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration TN-CYes
System configuration DCNo
System configuration ITNo
System configuration TNYes
System configuration TN-C-SYes
System configuration TTYes
System configuration TN-SYes
System configuration otherNo
Number of conductors (without earthing)-
Nominal voltage AC60V
Nominal discharge surge current (8/20)20kA
Max. continuous voltage DC-V
Max. PV-voltage-V
Max. continuous voltage AC75V
Max. discharge surge current (8/20)40kA
Nominal voltage DC-V
Max. overcurrent protection device, parallel connection (fuse)-A
Voltage protection level0.5kV
Construction size1 modular spacing
Integrated short-circuit protection selective to fuse gG-A
Voltage protection level L-N0.5kV
Voltage protection level N-PE-kV
Integrated short-circuit protectionNo
Max. overcurrent protection device, series connection (fuse)-A
With remote signalling contactNo
Max. conductor cross section solid (solid, stranded)35mm²
Short-circuit breaking capacity (Isccr)-kA
Max. conductor cross section flexible (fine-strand)35mm²
Signalling at the deviceOptic
Mounting methodDIN rail (top hat rail) 35 mm
Integrated backup fuseNo
Degree of protection (IP)IP20
Category type 2Yes
Leakage-current freeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

5095141 | V20-1-75

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration TN-C

System configuration DC

System configuration IT

System configuration TN

System configuration TN-C-S

System configuration TT

System configuration TN-S

System configuration other

Number of conductors (without earthing)

-

Nominal voltage AC

60V

Nominal discharge surge current (8/20)

20kA

Max. continuous voltage DC

-V

Max. PV-voltage

-V

Max. continuous voltage AC

75V

Max. discharge surge current (8/20)

40kA

Nominal voltage DC

-V

Max. overcurrent protection device, parallel connection (fuse)

-A

Voltage protection level

0.5kV

Construction size

1 modular spacing

Integrated short-circuit protection selective to fuse gG

-A

Voltage protection level L-N

0.5kV

Voltage protection level N-PE

-kV

Integrated short-circuit protection

Max. overcurrent protection device, series connection (fuse)

-A

With remote signalling contact

Max. conductor cross section solid (solid, stranded)

35mm²

Short-circuit breaking capacity (Isccr)

-kA

Max. conductor cross section flexible (fine-strand)

35mm²

Signalling at the device

Optic

Mounting method

DIN rail (top hat rail) 35 mm

Integrated backup fuse

Degree of protection (IP)

IP20

Category type 2

Leakage-current free