Technical specifications

Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting2520.0 - 6300A
Adjustment range undelayed short-circuit release9450.0 - 94500A
Rated permanent current Iu6300A
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally open contact0
Power loss767W
Integrated earth fault protectionNo
With switched-off indicatorYes
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Number of poles3
Position of connection for main current circuitBack side
Type of control elementPush button
Motor drive integratedNo
Degree of protection (IP)IP30
Complete device with protection unitYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA124977R1 | E6.3X6300EkipAwareLI3pFHR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

2520.0 .. 6300A

Adjustment range undelayed short-circuit release

9450.0 .. 94500A

Rated permanent current Iu

6300A

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally open contact

0

Power loss

767W

Integrated earth fault protection

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Number of poles

3

Position of connection for main current circuit

Back side

Type of control element

Push button

Motor drive integrated

Degree of protection (IP)

IP30

Complete device with protection unit

Motor drive optional