Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Number of poles (total)2
Built-in depth69mm
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Rated current20A
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicC
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Current limiting class3
Power loss5W
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Width in number of modular spacings2.0
Pollution degree2
Additional equipment possibleNo
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 16mm²
Over voltage category3
Connectable conductor cross section solid-core0.75 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS211103R0204 | SH201-C20NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Built-in depth

69mm

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated current

20A

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

C

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Power loss

5W

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Width in number of modular spacings

2.0

Pollution degree

2

Additional equipment possible

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 25mm²

Explosion-proof