Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of poles (total)2
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated current32A
Number of protected poles2
Voltage typeOther
Rated insulation voltage Ui440V
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss7.4W
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleNo
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 16mm²
Explosion-proofNo
Width in number of modular spacings2.0
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS212001R0325 | SH202-B32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

2

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated current

32A

Number of protected poles

2

Voltage type

Other

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.4W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Explosion-proof

Width in number of modular spacings

2.0

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.