Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated voltage230V
Number of poles (total)1
Number of protected poles1
Rated insulation voltage Ui440V
Release characteristicC
Rated impulse withstand voltage Uimp4kV
Rated current25A
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V3kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V3kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss3.2W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Additional equipment possibleNo
Width in number of modular spacings1.0
Connectable conductor cross section solid-core0.75 - 25mm²
Connectable conductor cross section multi-wired0.75 - 16mm²
Explosion-proofNo
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS231001R0254 | SH201T-C25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

230V

Number of poles (total)

1

Number of protected poles

1

Rated insulation voltage Ui

440V

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

3kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

3kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

3.2W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

1.0

Connectable conductor cross section solid-core

0.75 .. 25mm²

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Explosion-proof

Pollution degree

2