Technical specifications

Release characteristicD
Built-in depth69mm
Number of poles (total)1
Number of protected poles1
Rated insulation voltage Ui440V
Rated current13A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Voltage typeOther
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Power loss2.2W
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Over voltage category3
Pollution degree3
Width in number of modular spacings1.0
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS251001R0131 | S201-D13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Built-in depth

69mm

Number of poles (total)

1

Number of protected poles

1

Rated insulation voltage Ui

440V

Rated current

13A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Voltage type

Other

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

2.2W

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

1.0

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²